Brand Name : YONGXING

Model Number : DZL/SZL

Certification : ISO9001,ISO14001,SGS,BV

Place of Origin : HENAN

MOQ : 1set

Price : negotiable

Payment Terms : T/T, L/C, Western Union

Supply Ability : USD1000/SET

Delivery Time : 10-15days

Packaging Details : Nude packing,Package with Steel Box,or Wooden Box

Water Circulation : Natural Circulation

Installation : Assembled Boiler

Media : Water and Steam

Boiler Structure Level : Chain Grate,Single Drum,Threaded Pipe

Color : Customization

Pressure : Low pressure

Contact Now

Professional customized service coal fuel boiler and wood pellets boiler for food mill

Product Features
1. The coal-fired steam boiler produced by the company is a horizontal quick-loading boiler, and the water circulation mode is natural circulation. The boiler heat exchange system is composed of a drum, a left and right header, and a water-cooled wall, and the main heating surface is designed to install a furnace water wall. In addition, the main heating section of the boiler is made of seamless steel pipe for 20# low and medium pressure boiler, and the drum is made of special steel plate for boiler. The left and right headers are made of seamless steel tubes.


2. The boiler shaft is made of refractory concrete. The rear arch is low and long, so the combustion effect is good. The two-wing flue and the side wall brick are made of refractory sintered brick. General refractory bricks are used for the front and rear walls of the boiler.


3. The boiler is divided into two parts, one part includes the boiler body and the steel frame upper furnace wall, and the other part includes the coal hopper, the chain grate, the base steel frame and the lower furnace wall. Except for the middle partition wall construction, the other components are assembled and shipped. The tail cast iron economizer and the air duct of the boiler are shipped with the furnace.


4. The burning part adopts light chain grate, and the air enters on both sides. There are six independent air chambers under the grate. There are air conditioning mechanisms on both sides of the air chamber. The air is blown into the lower part of the base by the blower. The wind machine enters the independent wind room.


5. Avoid tube plate cracks: The flue of the boiler is designed on both sides of the main body, which not only allows the flue gas to smoothly enter the front smoke box, but also effectively reduces the temperature of the pipe and minimizes the crack of the boiler due to temperature stress.


6. High degree of automation: The boiler control system is a digital integrated controller based on PLC. The automatic controller can be set according to the user's combustion conditions. The operation is simple and convenient, automatic ignition, automatic feeding, automatic cleaning, and convenient operation. It also greatly improves the efficiency of boiler use.

Professional Coal Fired Steam Boiler Wood Pellet Steam Generator For Food Mill

Description----Conditions for the site before the boiler starts
1. The site is basically level and the fire, traffic and pedestrian roads are smooth. At least the ground floor of the plant should be rough ground. It is best to use the standard factory protection ground. The test site should have obvious signs and boundaries. The danger zone should have fences and warning signs.


2. The scaffolding in the boiler working area is completely removed, and the site is cleaned, which is in full compliance with the normal operating procedures of the boiler.


3. The ladders, walkways, railings and guards in the trial area should be put into use according to the installation.


4. The drainage channel is unblocked, and the channel and hole cover are complete.


5. The industrial, fire-fighting and domestic water systems of the trial operation area should be able to be put into normal use and have sufficient fire-fighting equipment.


6. The trial site has sufficient formal lighting. Accident lighting should be able to automatically invest in time when the fault occurs.


7. There should be a formal communication device for each running position. Temporary posts shall be added according to the requirements of the trial operation, and reliable communication facilities shall be provided.


8. Strengthen the anti-freeze measures in the boiler room.


9. Ensure proper ventilation and moisture resistance in the storage area of ​​biomass fuel.

Professional Coal Fired Steam Boiler Wood Pellet Steam Generator For Food Mill

Fault diagnosis and processing system features
1. Steam pressure over-limit protection: When the steam in the pot is over-pressure, the control system immediately enters the equipment to stop working, and the sound and light alarm is given. The screen displays “Vapor pressure is extremely high”. Until the fault is eliminated, press the reset button to cancel the alarm state.


2. Water shortage protection: When the boiler has a low water level failure due to pump failure or other reasons, the control system immediately turns off the burner power supply, enters the interlocking state, sound and light alarm until the fault is eliminated, and then press the reset button to cancel the alarm state.

The coal-fired steam boiler is mainly composed of six parts:

1). Feeding system. Including feed bin, vibrating feeder, screw feeder, spiral feed pipe, etc.

2). Combustion system. Including burners, fans, igniters, etc.

3). Ash removal system. The boiler's own ash removal system can regularly clean the furnace and the smoke pipe to ensure that there is no ash deposit on the surface of the pipe, so that the boiler can operate efficiently and continuously.

4). Air supply system. The boiler adopts the integrated arrangement of the air supply system and the burner, and the air is sent to the furnace through the blower through the blower to achieve the function of conveying fuel and supporting combustion.

5). Leading dust removal system. Under the action of the induced draft fan, the high-temperature flue gas generated after the completion of the combustion passes through the convective heat transfer in the pipe to enter the dust collector for purification, and finally is discharged by the chimney through the induced draft fan.

6). Automatic control system. The man-machine dialogue method is used to exchange information with the boiler to fully realize the automatic operation of the coal-fired steam boiler.

Welcome inquiry more specifications if u need

Technical paraments table QUICK INSTALLED BOILER

Data DZL1-T DZL2-T DZL3-T DZL4-T DZL6-T
Rated evaporation capacity t/h 1 2 3 4 6
Rated working pressure MPa 0.7/1.0/1.25 0.7/1.0/1.25 1.0/1.25 1.25/1.6 1.25/1.6
Rated steam temperature ℃ 170/184/194 170/184/194 184/194 194/204 194/204
Water-supply temperature ℃ 20 20 20 20 20
Body Heated area m2 6 54 83.5 115 186
Economizer Heated area m2 10.56 27.6 41.2 53 87.2
Chain Grate area m2 2.3 2.3 4.1 4.1 5.85
Exhaust temperature (℃) 120 120 120 125 125
Maximum shipping weight ton 19 25 28 32 43
Dimension(L*W*H)
mm
4500×2000×3200 5900×2200×3400 6200×2200×3450 6700×2400×3450 7700×2600×3600

TWO PART ASSEMBLED BOILER

TWO PART ASSEMBLED BOILER
boiler model Unit SZL6-1.25/1.6-AII SZL8-1.25/1.6-AII SZL10-1.25/1.6-AII SZL12-1.25/1.6-AII SZL15-1.25/1.6-AII SZL20-1.25/1.6-AII SZL25-1.25/1.6-AII
capacity ton/h 6 8 10 12 15 20 25
rated pressure Mpa 12.5/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6
rated steam temeperature 193/204 193/204 193/204 193/204 193/204 193/204 193/204
feed water temperature 105 105 105 105 105 105 105
radiation area m2 18.19 22.14 25.8 25.8 34.117 53.78 99.21
convection area m2 121.9 158.86 200.38 250.17 331.616 411.8 457.78
economizer area m2 53.13 104.64 130.8 174.4/261.1 117.72/117.2 212.4 476.16
valid grate area m2 7.55 9.34 10.98 12.78 16.24 20.84 24.76
applicable fuel COAL COAL COAL COAL COAL COAL COAL
exhaust gas temperature 165.78/169.85 161/165 160/162 158/150 156.7/159.4 153/159 152/156
design efficiency % 80.11/79.44 79.95/79.98 80.55/80.28 80.68/80.72 80.48/80.56 81.09/80.77 81.38/81.26
fuel consumption kg/h 863.28/874.78 1153.42/1161.38 1430.96/1442.74 1714.5/1721.8 2167.89/2164.7 2868.63/2884.7 3551/3556
max part size for delivery mm 7100*2800*3500
7300*2540*2330
7300*3000*3500
7400*2700*2330
7600*3200*3500
7700*2900*2330
7600*3200*3500
8500*2900*2330
7350*3373*3505
8904*3370*1100
7814.7*3573*3511
9439*3768*1100
8478*2600*2740
Bulk packing


Product Tags:

coal fired water tube boiler

      

coal fired hot water boiler

      
Wholesale Professional Coal Fired Steam Boiler Wood Pellet Steam Generator For Food Mill from china suppliers

Professional Coal Fired Steam Boiler Wood Pellet Steam Generator For Food Mill Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Yong Xing Boiler Group Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)